Investigating the Effect of Rank and Angle Parameters on the Image Quality of the Gamma Camera at Long Distances

Document Type : Original Article

Authors

1 Master's student, Imam Hossein (AS) University, Tehran, Iran

2 Assistant Professor, Imam Hossein (AS) University, Tehran, Iran

3 PhD student, Imam Hossein (AS) University, Tehran, Iran

Abstract

Gamma-ray imaging is the most essential way to identify unknown gamma-ray emitting objects in nuclear security and safety, such as preventing nuclear terrorism. The mask parameters of a coded aperture are critical design features when optimizing the performance of a gamma-ray camera. This paper presents the results of the effect of the mask rank on the image quality of a lead-based coded-aperture imaging (CAI) with a mosaic-modified uniformly redundant array (MURA) mask using the Monte Carlo Gate code. The impact of three ranks of 5, 11, and 19 on the image quality is quantified. The imaging of a surface cesium-137 source with an activity of 0.02 mCi sitting at a distance of 3 m from the system at the three angles of 0, 25, and 45 degrees was demonstrated using maximum likelihood expectation maximization (MLEM) method. To evaluate the quality of the reconstructed images, the peak signal-to-noise ratio (SNR) of the captured gamma camera images was evaluated as a function of the mask rank and viewing angle. In order to find the most appropriate distance between the mask and the detector in the optimal performance of the gamma camera imaging system, the distance between the mask and the detector was investigated at three distances of 3, 6 and 12 cm. The results showed that the MURA mask with rank 19, which is located at a distance of 3 cm from the detector, has a higher signal-to-noise ratio and lower angular error than masks with ranks 5 and 11, and therefore it is suitable for use in gamma cameras with security application.

Keywords

Main Subjects


Smiley face

 

  • [1] Shakur, H. “ Getting to know the threats of modern warfare in the field of radiation”; Imam Hossein Officer and Guard Training University. 2021, 190, 154-156 (in Persian).
  • [2] Cieślak, M.; Gamage, K.; Glover, R. “Coded-Aperture Imaging Systems: Past, Present and Future Development E A Review”; Meas. 2016, 92 , 59-71. doi.org/10.1016/j.radmeas.2016.08.002
  • [3] Saha, G. “Fundamentals of Nuclear Pharmacy”; 2004, Springer.
  • [4] Park, S.; Boo, J.; Hammig M.; Jeong, M. “Impact of Aperture-Thickness on the Real-Time Imaging Characteristics of Coded-Aperture Gamma Cameras“; N Eng. Technol. 2021, 53, 1266-1276. doi.org/10.1016/j.net.2020.09.012
  • [5] Meißner, T.; Nahm, W.; Hesser, J.; Löw, N. “Simulation Study on Super-Resolution for Coded Aperture Gamma Imaging”; arXiv:2306.08483 [physics.Med-Ph], 2023.org/10.48550/arXiv.2306.08483
  • [6] Liu, Y.; Shuai, L.; Li, D.; Liu, S.; Wang, Y.; Zhou, W.; Huang, H.; Wang, X.; et al. “High-Sensitivity Stereo Coded Aperture Gamma Camera for Three-Dimensional Localization of Radioactive Hotspots”; AIP Adv. 2022. 12. org/10.1063/5.0096865
  • [7] He, W. ; Wang, Y.; Liang, X.; Zhou, W.; Zhu, Z.; Han, H.; Zhai, J.; Zeng, X.; Feng, B.; Tang, H.; Li, D.; Long Wei, Z.Z.; Huang, X. “High-Performance Coded Aperture Gamma Camera Based on Monolithic GAGG:Ce Crystal”; ISO4 Appl. Radiat. Isot. 2021, 92. doi.org/10.1063/5.0035991
  • [8] Zhu, B.; Wang, Z.; Gao, T.; Chen, Q.; Huang, Q.; Mao, X.; Zhao, C.; Tao, M.; Qi, P.; Zhao, Q.; Chaowen Yang, Y.L.R.Z. “A New Contrast-to-Noise Ratio for Image Quality Characterization of a Coded-Aperture Gamma Camera”; ISO4 Appl. Radiat. Isot. 2021. doi.org/10.1016/j.apradiso.2021.109592
  • [9] Hashemi, S. ; Hosseinkhani, P.; Shakur, H. “Simulation And Performance Evaluation of Coded Aperture Gamma Imager System with Wide Field of View”; Measurement and radiation safety 2023, 12, 111-120 (in Persian). doi.org/10.22052/rsm.2023.252810.1020
  • [10] Lee, H.; Kim, J.; Lee, J.; Hyeong Kim, C. “Development And Performance Evaluation Of Large-Area Hybrid Gamma Imager (LAHGI)”; Eng. Technol. 2021, 53, 2640-2645. doi.org/10.1016/j.net.2021.01.036

 

Volume 14, Issue 4 - Serial Number 54
January 2024
Pages 265-272
  • Receive Date: 20 September 2023
  • Revise Date: 02 October 2024
  • Accept Date: 23 April 2024
  • Publish Date: 21 January 2024